Rated supply voltage | 24 VDC, If power supply incorporates a single-phase full-wave rectifier. |
---|---|
Operating voltage range | 85% to 110% of rated supply voltage |
Power consumption (Relay ON) | Approx. 1.1 W (at 24 VDC) |
Power consumption (Relay OFF) | Approx. 0.1 W (at 24 VDC) |
Reset voltage | 10% max. of rated supply voltage |
Number of time ranges | 1 |
Time ranges | 0.2 s to 5 s |
Operating mode | Power ON-delay |
Control output Type | Time-limit: 4PDT |
Control output (Contact output) |
Switching capacities (resistive load (cos(phi)=1)): 250 VAC 3 A Minimum applicable load: 1 mA at 1 VDC (failure level: P) |
Operating resetting | Time-limit operation/Self-reset |
Ambient temperature |
Operating: -10 to 50 CEL Storage: -25 to 65 CEL (with no icing) |
Ambient humidity | Operating: 35 to 85% RH |
Accuracy of operating time | +/- 1% max. (FS) |
---|---|
Setting error | -10 to 10% (FS) |
Reset time | 0.1 s max. (including halfway reset) |
Influence of voltage | +/- 2% FS max. |
Influence of temperature | +/- 2% FS max. |
Insulation resistance | 100 MOhm min. (at 500 VDC) |
Dielectric strength |
between current-carrying metal parts and exposed non-curernt-carrying metal parts: 2000 VAC, 50/60 Hz for 1 min (Terminal screw sections are not excluded) between control output terminals and operating circuit: 2000 VAC, 50/60 Hz for 1 min between contacts of different polarities: 1500 VAC, 50/60 Hz for 1 min between non-continuous contacts: 1000 VAC, 50/60 Hz for 1 min |
Impulse withstand voltage |
between power terminals: 1 kV between exposed non-current-carrying metal parts: 1.5 kV |
Noise immunity | +/- 1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 us, 1-ns rise) |
Static immunity | Mulfunction: 4 kV Destruction: 8 kV |
Vibration resistance (Destruction) | 10 to 55 Hz, 0.75 mm single amplitude each in X, Y, and Z directions for 1 hours |
Vibration resistance (Malfunction) | 10 to 55 Hz, 0.5 mm single amplitude each in X, Y, and Z directions for 10 min |
Shock resistance (Destruction) | 1000 m/s**2, 3 times each 6 directions |
Shock resistance (Malfunction) | 100 m/s**2, 3 times each 6 directions |
Mechanical Life expectancy (relay output) | 10000000 operations min. (under no load at 1800 operations/h) |
Electrical Life expectancy (relay output) | 200000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h) |
Degree of protection | IEC60529(JEM): IP40 |
Applicable standard (UL) |
Standard No.: UL508 File number: E41515 |
Applicable standard (CSA) |
Standard No.: CSA C22.2 No.14 File number: LR22310 |
Applicable standard (LR) | 97/10016 |
Applicable standard (CCC) | Printed |
Applicable standard (EC Directive (Machinery Directive) ) | EN61812-1 |
Applicable standard (EC Directive (Low Voltage Directive) ) |
EN61812-1 IEC60664-1 2.5 kV/1 |
Applicable standard (EC Directive (EMC Directive) ) |
EMI: EN61812-1 Emission Enclosure: EN55011 Group1 class A Emission AC mains: EN55011 Group1 class A EMS: EN61812-1 Immunity ESD: IEC61000-4-2(8 kV air discharge) cRF-interference: IEC61000-4-3(10 V/m, AM radio waves (80 MHz to 1 GHz)) Immunity Burst: IEC61000-4-4(2 kV power-line and I/O signal-line) Immunity Surge: IEC61000-4-5(1 kV line to line, 2 kV line to ground) |
External connection method | Plug-in terminal |
Case color | Munsell 5Y7/1 (Light gray) |
Weight |
Approx. 50 g |